Description |
In the pursuit of reducing air borne bacteria in operation rooms, laminar air flow system provides a controlled distribution of biologically clean air at the operating table, while reducing the risk of contamination from outside the clean zone.
The range of laminar air flow ceilings ensures efficient protection against contamination which can occur during invasive acts and caused by airborne dead or living particles. The designed air flow velocity reduce the uncomfortable feeling of air breezing.
Features |
∎ Modular construction, easy installation and filters replacement.
∎ Unique design to deliver ultra clean air over the operating table downwards and outwards.
∎ The ceilings are available in different dimensions and meet with DIN 1946 European standards.
∎ Mini pleat HEPA / ULPA filters
∎ Air tight sealing tape
∎ Perforated stainless steel diffuser
∎ Central duct for operating table light stem
Laminar Flow Strategies |
Laminar air flow one-pass systems are used to bathe an area in a uniform, continuous shower of filtered ultra-clean air. The laminar ceiling panel is designed to minimize mixing (non-aspirating), while providing a unidirectional air stream that is perpendicular to a perforated panel. Particle control is achieved by removing the particles from the source, and away from a defined critical area. Air distribution systems for particle control will typically consist of vertical laminar flow.
Specification |
Model | Dimension (L x W x H) mm | Duct Connection (mm) | H13/14 HEPA (mm) | Air Velocity (m/s) | Air Flow Rate (m3/h) |
2014 | 2000 x 1400 x 450 | 540 x 180 (2 Pcs) | 1220 x 610 x 69 (2 Pcs) | 0.15 0.20 0.25 0.30 | 1500 2000 2500 3000 |
2418 | 2400 x 1800 x 450 | 540 x 180 (2 Pcs) | 1525 x 610 x 69 (2 Pcs) | 0.15 0.20 0.25 0.30 | 2300 3000 3800 4600 |
2720 | 2700 x 2000 x 450 | 690 x 180 (2 Pcs) | 1830 x 762 x 69 (2 Pcs) | 0.15 0.20 0.25 0.30 | 2900 3880 4860 5800 |
Other dimensions of casing and HEPA are customizable.
Detailed Images |
∎ Option One:
· Casing:Hot dip galvanized steel powder coated
· Facing cover:Stainless steel
∎ Option Two:
· Casing:Stainless steel
· Facing cover:Stainless steel
∎ HEPA Filter:
DOWNLOAD
Down load Date sheet: Operation Room Laminar Flow Ceiling Diffuser
Ordering Info
1. Outer dimension: length, width, height (by manufacturer’s standard if not provided).
2. Air flow rate: required for verification of dimension.
3. Air filter grade: H13 (as default), H14, U15.
4. Material of construction:
Casing: steel sheet powder coated (recommended), stainless steel 201, stainless steel 304.
Perforated facing plate: steel sheet powder coated, stainless steel 201, stainless steel 304 (recommended).
Damper: the buyer to specify if not same with casing material.
5. Optional: LED panel lights, standard width 300mm.
NEXT: HEPA Box Diffuser